5 Steps for Testing and Maintenance of Benchtop Fume Hood

Benchtop Ductless Fume Hoods

A benchtop fume hood is a cost-effective and compact option for static fume hoods depending on the application. The top bench hoods are ideal for smaller footprint installations, laboratories, and workspaces, and can be moved easily on and off-site.

A fixed floor fume hood is typically large stationary equipment that is normally positioned at a standing height on five sides of the work area. These fume hoods are generally more expensive because of their size and ideal for installations with enough space. The two main types are duct and ductless fumes. Both work on the same principle that air is drawn to the workplace and internal air is expelled. Benchtop duct fume hoods are suitable for industrial and laboratory applications where a ventilation system is available. Due to the energy cost associated with heating, cooling, and air dissipation, ducted systems are more expensive in comparison to a ductless fume hood. The quality of the air and public safety discharge sites must also be taken attentively.

Whereas ductless benchtop fume hoods are a mobile alternative to ducted fume hoods that are economical and environmentally friendly. They include an integrated ventilation system, which re-circulates the air filtered through the enclosed system. They can easily be pushed on or off the spot where an electrical plug is visible. Ductless fume hoods are fully installed, making installation minimal and less maintenance-efficient than comprehensive ventilation systems.

Usually, fume hoods are used for storage and exhaust gases in laboratories. If the hoods do not operate, the room control for a room controlled by variable air volume is almost equal to normal occupancy. When the hoods operate, the control system senses indoor and outdoor flows and pressures, hoods, and conduits and adjusts the temperature, moisture, and room pressure to ensure that the room is kept under pressure. One of the most important things is to do   benchtop fume hood maintenance and testing so that people can use it for a long time without any interruption. 

For the same people can go through the 5 Steps for Testing and Maintenance of Benchtop Fume Hood:

  1. Ensure sufficient face velocities: Before each use; hoods should be checked by the user to ensure sufficient face velocities, as the fume hood does not have adequate flow rates for the required work and lack of excessive turbulence. Switch off tools and accessories on the hood and reduce the shape when the exhaust system fails. Leave off the area immediately.
  1. Accreditation is essential for the safe work: Fume hoods should be certified to ensure that they work safely, at least annually. Typical tests include facial velocity measurements, tracer gas checks, and containment. Tracer gas containment tests are especially relevant because studies have shown that face velocity is not a reasonable predictor of leakage of the hood fumes. Fume hoods are among the most important devices used and misused for hazard monitoring.
  1. Protection against harmful exposure: Consumers should recognize the very critical elements that protect against potentially damaging risks by combining safety glasses, protective gloves, laboratory smocks, and good practices, and a smoke hood. Remember always the person who is most likely to get hurt is the hood user. The escape from harmful material into the laboratory can also affect all laboratory occupants.
  1. How it is designed to protect: fume hoods cover users only when used properly and when running properly. A fume hood is designed to avoid vapor, aerosol, toxic chemicals, odorous substances, and other harmful substances from exposure to occupants and rooms. As a defensive shield, it is a secondary objective to deal with a potentially explosive or extremely transparent reactive material.
  1. What should be done when the repair is needed: The performance monitoring typically involves an assessment of the face speed, sound, storage, ability to control and track a VAV. Note any observed strength, sash, ignorance, plumbing, lighting, or problems with corrosion. If an inspection fails, they need to be removed before they are fixed.

Now, everyone is aware of the maintenance as well as tips to testing the Benchtop Fume Hood, which will be helpful for its users to enjoy the services of benchtop fume hoods for a long for.

Moving forward, if there is anyone, who wants to understand other things related to benchtop fume hoods can contact us  Our experienced employees will be there to assist the customers.

If there is any concern regarding our highly rated services don’t hesitate to get in touch with us. We are happy to assist our customers.